Pump groups

HydroCon Fresh 115-400

Fresh water station

Ready for operation with integrated FWR 400 fresh water controller
House and apartment station for detached houses, terraced houses and apartments – For supplying drinking water by the flow-through principle. Compact design for wall mounting, including thermal insulation case.  
Article Description
1403HS-FWR01-1A-G HydroCon Fresh 115-400
1403HS-FW-ZIRK-1A-G Circulation extension for HydroCon Fresh 115-400

HydroCon HKM 200

Standalone Heating Circuit Mixer Module

Heating circuit mixer module with integrated heating circuit controller, pre-wired with ProBusX or Modbus
Two line pump module, pipe clearance 125 mm, equipped with Class A high-efficiency pump with PWM actuation. Optionally with Halm or Grundfos pump. Supply line and return line ball cock with thermometer handle 0 – 160°C. The supply line ball cock is equipped with an adjustable gravity brake. A three-way mixer is integrated between the supply line and the return line. All the electronic components of the drives are situated outside the insulation and are air-cooled. The supply line and return line are equipped in addition with a shut-off valve for boiler connections. The mixer and the pump can be replaced without the system needing to be emptied.  
Article Description
1402HS-HKG02-1B-G HydroCon HKM 200 DN20

HydroCon HWS 20-650

20 kW house and apartment station for the use of local and district heating

Ready for operation with integrated grandis 650 HK system controller
Direct supply of the heating circuits and indirect hot water supply via a drinking water storage tank. Compact design for wall mounting, including thermal insulation case. Pre-wired ready for operation with integrated controller.  
Article Description
1402HS-HWS-20-650-1A-G HydroCon HWS 20-650

HydroCon LKM 400-DN25

System-Baugruppe zur optimalen Pufferbeladung durch Feststoffkessel

System-Baugruppe mit integrierter Steuerung zur Anbindung eines Festbrennstoffkessels an einen Pufferspeicher. Die intelligente Beladung führt zu einer schnellen Erwärmung des oberen Pufferspeicherbereiches und einer optimalen Anbindung des Feststoffkessels durch Rücklauftemperaturregelung mittels Mehrwegemischer und Durchflussregelung über die Drehzahlregelung der Hocheffizienzpumpe. Vormontiert, vorverdrahtet, auf Dichtheit geprüft, optimale Wärmedämmung, mit integrierter Steuerung.  
Artikel Beschreibung
1402HS-LKM01-1A-G HydroCon LKM400 DN25

HydroCon SOL 250

Intelligent Solar Pump Module for Immediate Installation

Pre-wired system module with integrated solar controller primos 250 SR
Two line pump module, pipe clearance 125 mm, equipped with Class A high-efficiency pump with PWM actuation. Supply line and return line ball cock with thermometer handle 0 – 160°C. The return line ball cock is equipped in addition with an adjustable gravity brake. An automatic permanent deaerator is used in the solar supply line. In the return line there is a lockable fill and rinse valve which is also used for measuring and setting the flow. Fully pre-wired with integrated control system.
Article Description
1401HS-SOL01-1B-G HydroCon SOL 250 7m, DN20, solar station

HydroCon SOLT 15-650

Solar Separation Unit

Pre-wired system sub-assembly with integrated solar and heating circuit control unit grandis 650 HK
Equipped with a high-efficiency pump class A from Wilo. Flow meter in the solar circuit and buffer circuit. Heat exchanger for 15 kW. For collector surfaces up to 25 m. Pre-wired for direct operation.
Article Description
1401HS-SOLT15-650-1A-G HydroCon SOLT 15-650, solar separation unit
1401HS-SOLT15-1A-G Solar separation unit without controller

HydroCon SOLT 25-650

Solar multi-layer charging unit

Ready for operation with integrated system controller grandis 650 HK
Equipped with a high-efficiency pump class A from Wilo. Flow meter in the solar circuit and buffer circuit. Heat exchanger for 25 kW. For collector surfaces up to 50 m . Pre-wired for direct operation.
Article Description
1401HS-SOLT25-650-1A-G HydroCon SOLT 25-650, solar layer station
1401HS-SOLT25-1A-G Solar layer station without controller

HydroFlex HKM 200

Pump group mit integrated control system

Heating Circuit Mixer Module for Immediate Installation. Pre-wired system module with integrated control system compatible with REGULA grandis 650 HK via bus cablle.
Two line pump module, pipe clearance 125 mm, equipped with Class A high-efficiency pump with PWM actuation. Optionally with Halm or Grundfos pump. Supply line and return line ball cock with thermometer handle 0 – 160°C. The supply line ball cock is equipped with an adjustable gravity brake. A three-way mixer is integrated between the supply line and the return line. All the electronic components of the drives are situated outside the insulation and are air-cooled. The supply line and return line are equipped in addition with a shut-off valve for boiler connections. The mixer and the pump can be replaced without the system needing to be emptied.
Article Description
1402HS-HKG01-1E-G HydroFlex HKM200 DN20
1402HS-HKG07-1E-G HydroFlex HKM200 DN20 without display

HydroFlex HKM 300-DN25

Pump group with integrated electronics

Pre-wired system module with integrated electronics, compatible with grandis 650 HK via BUS cable. Ready for connection, no additional electrical installation work required.
Twin-line pump group, tube spacing 125 mm, equipped with a high-efficiency pump Class A. Supply line and return flow ball valve with thermometer handle 0 – 120 °C. The return flow ball valve is equipped with an adjustable gravity brake.. A threeway mixer is integrated between the supply line and the return line. The supply line and return line are equipped in addition with a shut-off valve for boiler connections. The mixer and the pump can be replaced without the system needing to be emptied. Based on Tuxhorn tubra® - duotherm pump module.
Pre-assembled, pre-wired, tested for leaks, optimum thermal insulation, with integrated electronics.  
Article Description
1402HS-HKG05-1A-G HydroFlex HKM300 DN25
1402HS-HKG08-1B-G HydroFlex HKM300 DN25 without display

HydroFlex HKM 400-DN25

System module with 4-way mixer and integrated electronics

Pre-wired system module with integrated electronics, compatible with grandis 650 HK via BUS cable Twin-line pump group, tube spacing 125 mm, equipped with a high-efficiency pump Class A. Supply line and return flow ball valve with thermometer handle 0 – 120 °C. The return flow ball valve is equipped with an adjustable gravity brake. Thanks to the 4-way bivalent mixer installed, two different heat sources (e.g. two levels of a buffer storage tank) can be used particularly efficiently. Based on Tuxhorn tubra® - duotherm pump module. Pre-assembled, pre-wired, tested for leaks, optimum thermal insulation, with integrated electronics.
Article Description
1402HS-HKG06-1A-G HydroFlex HKM400 DN25
1402HS-HKG09-1A-G HydroFlex HKM400 DN25 without display

HydroFlex HKU 200

Pump group with integrated control system

Pre-wired system module with integrated control system compatible with REGULA grandis 650 HK via bus cable
Two line pump module, pipe clearance 125 mm, equipped with Class A high-efficiency pump with PWM actuation. Optionally with Halm or Grundfos pump. Supply line and return line ball cock with thermometer handle 0 – 160°C. The supply line ball cock is equipped with an adjustable gravity brake. The electronic components of the pump is situated outside the insulation and is air-cooled. The supply line and return line are equipped in addition with a shut-off valve for boiler connections. The pump can be replaced without the system needing to be emptied.  
Article Description
1402HS-HKU01-1B-G HydroFlex HKU200 DN20