HydroCon Fresh 115-400
Fresh water station
Ready for operation with integrated FWR 400 fresh water controller House and apartment station for detached houses, terraced houses and apartments – For supplying drinking water by the flow-through principle. Compact design for wall mounting, including thermal insulation case.Article | Description |
---|---|
1403HS-FWR01-1A-G | HydroCon Fresh 115-400 |
1403HS-FW-ZIRK-1A-G | Circulation extension for HydroCon Fresh 115-400 |
Categories: Fresh water, Pump groups
- General Details
- Technical Data
- Downloads
General Details
- ensulated heat exchanger
- Station in EPP thermal insulation case
- Fittings made of hygienic materials suitable for drinking water
- Volumetric flow sensor in the cold water inlet
- Temperature sensors for cold water, hot water, supply line and return flow
- Grundfos UPM3 Hybrid pump – Performance-controlled
- Non-return valve and DVGW shut-off ball valve
- Stainless steel tube 1.4404
- Copper-soldered stainless steel plate heat exchangers – Plates: 1.4404
- Primary max. operating temperature 85 °C
- Integrated fresh water controller, pre-cabled
- Circulation module (optional)
- Cascade (optional on request)
- Pipelines with thermal and acoustic insulation
Technical Data
Techincal data of fresh water station
Hot drinking water performance: | up to 115 kW at 75°C HZ-VL-PR | Fittings: | Hygienic materials suitable for drinking water according to DVGW, UBA, WRAS Pluming: CW617N; Heating: CW617N, CW614N |
Hot drinking water tapping rate: | up to approx. 35 l/min | Seals: | according to the requirements of DVGW KTW D1/ D2, W270, WRAS |
Min. inlet pressure: | 1,5 bar | Thermal insulation: | EPP |
Max. operating pressure: | PN10 | Heat exchanger plates: | 1.4404; Solder: Copper |
Hot drinking water temperature: | 60°C | Pipeline | 1.4401 |
Cold drinking water temperature: | 10°C | Dimensions incl. insulation: | H x W x D in mm 450 x 700 x 282 |
Primary max. operating temperature: | 85°C | Weight: | approx. 15,5 kg |
Primary min. operating temperature: | 5°C | ||
Primary max. operating pressure: | PN6 |
Technical data of the control system
Operating voltage: | AC 230 Volt, 50 Hz, -10 to +15% | Dimensions of the terminal: | H x W x D in mm 144 x 102 x 11 |
Standby losses: | 1 W | Protection class: | IP30 according to DIN 40050, EN 60529 |
Display: | LCD | Housing material: | 100% recyclable ABS housing |