Our service for you
At Prozeda, we work hand-in-hand with our solar and heating
systems installer partners in order to provide them with the
best possible solutions. As a special service we offer configurations of example systems.
You can download the parameter files, you can use them as they are, or modify them according to your needs. And you can of course use the layouts for you conexio 200.
Please note, that the following system layouts parameter settings for grandis 650 HK V2. They are not to be understood as a complete hydraulic circuit diagrams and are only example layouts.
Also, you must verify all settings and parameters carefully before applying in real systems.
Layout 110.00 + 1 mixed heating circuit.
1 solar circuit (1 collector - 1 storage tank), PWM pump with minimum speed
control 30%.
1 mixed heating circuit, linear heating curve. Hot water function.
Layout |
Parameters |
Record |
![]() |
Layout 110.00 + 1 mixed heating circuit + wood-fired boiler.
1 solar circuit (1 collector - 1 storage tank), both PWM pumps with minimum
speed control 30%.
1 mixed heating circuit, linear heating curve. Hot water function
Wood-fired boiler over Multi-function controller.
Layout |
Parameters |
Record |
![]() |
Layout 111.00 + 1 mixed + 1 unmixed heating circuit.
1 solar circuit (1 collector - 1 storage tank), both PWM pumps with minimum
speed control 30%.
1 mixed heating circuit, linear heating curve. Hot water function.
1 unmixed heating circuit.
HW reheating with 3-way valve.
Layout |
Parameters |
Record |
![]() |
Layout 110.00 + 2 mixed heating circuits.
1 solar circuit (1 collector - 1 storage tank).
2 mixed heating circuits, linear heating curve. Hot water function.
Layout |
Parameters |
Record |
![]() |
Layout 110.00 + 2 mixed heating circuits + wood-fired boiler.
1 solar circuit (1 collector - 1 storage tank), PWM pump with minimum speed
control 30%.
2 mixed heating circuits, linear heating curve. Hot water function with pump.
Layout |
Parameters |
Record |
![]() |
Layout 210.01 + 2 mixed heating circuits + wood-fired boiler.
2 solar circuits (1 collector - 2 loading zones), PWM pump with minimum speed
control 30%.
2 mixed heating circuits - one of them with flex module flex 400 or Hydroflex
module, linear heating curve. Hot water function with pump.
Layout |
Parameters |
Record |
![]() |
Layout 210.01 + 2 mixed heating circuits + wood-fired boiler.
2 solar circuits (1 collector - 2 storage tanks), PWM pump with minimum speed
control 30%.
2 mixed heating circuits - one of them with flex module flex 400 or Hydroflex
module, linear heating curve. Hot water function with pump.
Layout |
Parameters |
Record |
![]() |
Layout 210.01 + 1 mixed heating circuit.
2 solar circuits (1 collector - 1 storage tank - 1 pool), PWM pump with minimum
speed control 30%. (Pump R3 over MFC).
1 mixed heating circuit, linear heating curve. Hot water function.
Layout |
Parameters |
Record |
![]() |
Layout 211.01 + 1 mixed heating circuit.
2 solar circuits (1 collector - 1 storage tank - 1 pool), PWM pump with minimum
speed control 30%. (Pump R4 over MFC).
1 mixed heating circuit, linear heating curve. Hot water function.
Layout |
Parameters |
Record |
![]() |